Scientific practice¶
VIPP makes intermediate outputs easier to see; it cannot decide whether those outputs answer a biological question correctly. A defensible workflow combines visible processing with representative data, independent references, and a frozen evaluation procedure.
Minimum analysis lifecycle¶
flowchart TD
Q["Define the biological quantity"] --> D["Select representative development data"]
D --> T["Build and tune while inspecting intermediates"]
T --> R["Freeze workflow, software, and decision rules"]
R --> V["Evaluate on held-out references"]
V --> B["Run the collection"]
B --> A["Audit outputs and report exclusions"]
Four questions to ask¶
- What is the target? A nucleus, punctum, branch, event, overlap, or intensity summary needs an operational definition.
- What can vary? Include acquisition day, operator, treatment, tissue, signal level, artifact, and biological heterogeneity in representative data.
- What is independent evidence? Reference annotations, calibrated phantoms, known synthetic truth, or a justified external method should not be the same output used to tune the workflow.
- What would make the workflow fail? Predefine failure/QC criteria before seeing all experimental results.
Continue by decision¶
- Choose 2D or 3D before building spatial nodes.
- Tune without fooling yourself before a parameter sweep.
- Validate a workflow before drawing biological conclusions.
- Report a VIPP analysis before sharing or publishing.
Inspection is necessary, not sufficient
A plausible overlay can still be biased, inconsistent, or wrong outside the inspected field. Conversely, a strong aggregate metric can hide systematic boundary errors. Use visual and quantitative evidence together.